63 research outputs found

    Calibration developments for multicamera optical tracking systems

    Get PDF
    Intra-Operative Electron Radiation Therapy (IOERT) is a technique for cancer treatment that delivers a high dose of radiation directly to the post-resected tumour bed or to an unresected tumour during surgery. Recently, a tracking system (OptiTrack, NaturalPoint Inc., USA) was installed into the operating room that allows for navigation and thus assist oncologists in the treatment planning of this procedure. The system is an optical tracking system composed of eight independent cameras, and then a calibration process is required for a correct tracking performance. The current state consists on calibrating just before every IOERT procedure, increasing surgery preparation time by approximately one hour. In order to study the feasibility of defining new calibration protocols based on calibrating every certain period of time, this projects assess the temporal stability of tracking system calibrations and determines an optimum methodology for the detection of miscalibration within the tracking system. To achieve this, software applications were developed to control the Optitrack system by means of the Application Programming Interface provided by the vendor. Also, a group of experiments were performed using developed applications to acquire tracking data. Results show the temporal stability of the tracking system calibration during five days, and the feasibility of detecting tracking system miscalibrations by using the proposed methodology. This study will allow the hospital to save time and resources by stablishing protocols for calibration in which calibration is performed every 2-5 days. The calibration state of the system will be evaluated before every surgery in order to determine if the system needs to be calibrated or not following a proposed methodology (with an average duration of 5 minutes).Ingeniería Biomédic

    Optimization of craniosynostosis surgery: virtual planning, intraoperative 3D photography and surgical navigation

    Get PDF
    Mención Internacional en el título de doctorCraniosynostosis is a congenital defect defined as the premature fusion of one or more cranial sutures. This fusion leads to growth restriction and deformation of the cranium, caused by compensatory expansion parallel to the fused sutures. Surgical correction is the preferred treatment in most cases to excise the fused sutures and to normalize cranial shape. Although multiple technological advancements have arisen in the surgical management of craniosynostosis, interventional planning and surgical correction are still highly dependent on the subjective assessment and artistic judgment of craniofacial surgeons. Therefore, there is a high variability in individual surgeon performance and, thus, in the surgical outcomes. The main objective of this thesis was to explore different approaches to improve the surgical management of craniosynostosis by reducing subjectivity in all stages of the process, from the preoperative virtual planning phase to the intraoperative performance. First, we developed a novel framework for automatic planning of craniosynostosis surgery that enables: calculating a patient-specific normative reference shape to target, estimating optimal bone fragments for remodeling, and computing the most appropriate configuration of fragments in order to achieve the desired target cranial shape. Our results showed that automatic plans were accurate and achieved adequate overcorrection with respect to normative morphology. Surgeons’ feedback indicated that the integration of this technology could increase the accuracy and reduce the duration of the preoperative planning phase. Second, we validated the use of hand-held 3D photography for intraoperative evaluation of the surgical outcome. The accuracy of this technology for 3D modeling and morphology quantification was evaluated using computed tomography imaging as gold-standard. Our results demonstrated that 3D photography could be used to perform accurate 3D reconstructions of the anatomy during surgical interventions and to measure morphological metrics to provide feedback to the surgical team. This technology presents a valuable alternative to computed tomography imaging and can be easily integrated into the current surgical workflow to assist during the intervention. Also, we developed an intraoperative navigation system to provide real-time guidance during craniosynostosis surgeries. This system, based on optical tracking, enables to record the positions of remodeled bone fragments and compare them with the target virtual surgical plan. Our navigation system is based on patient-specific surgical guides, which fit into the patient’s anatomy, to perform patient-to-image registration. In addition, our workflow does not rely on patient’s head immobilization or invasive attachment of dynamic reference frames. After testing our system in five craniosynostosis surgeries, our results demonstrated a high navigation accuracy and optimal surgical outcomes in all cases. Furthermore, the use of navigation did not substantially increase the operative time. Finally, we investigated the use of augmented reality technology as an alternative to navigation for surgical guidance in craniosynostosis surgery. We developed an augmented reality application to visualize the virtual surgical plan overlaid on the surgical field, indicating the predefined osteotomy locations and target bone fragment positions. Our results demonstrated that augmented reality provides sub-millimetric accuracy when guiding both osteotomy and remodeling phases during open cranial vault remodeling. Surgeons’ feedback indicated that this technology could be integrated into the current surgical workflow for the treatment of craniosynostosis. To conclude, in this thesis we evaluated multiple technological advancements to improve the surgical management of craniosynostosis. The integration of these developments into the surgical workflow of craniosynostosis will positively impact the surgical outcomes, increase the efficiency of surgical interventions, and reduce the variability between surgeons and institutions.Programa de Doctorado en Ciencia y Tecnología Biomédica por la Universidad Carlos III de MadridPresidente: Norberto Antonio Malpica González.- Secretario: María Arrate Muñoz Barrutia.- Vocal: Tamas Ung

    New Technologies to Improve Surgical Outcome during Open-Cranial Vault Remodeling

    Get PDF
    Current approaches for the surgical correction of craniosynostosis are highly dependent on surgeon experience. Therefore, outcomes are often inadequate, causing suboptimal esthetic results. Novel methods for cranial shape analysis based on statistical shape models enable accurate and objective diagnosis from preoperative 3D photographs or computed tomography scans. Moreover, advanced algorithms are now available to calculate a reference cranial shape for each patient from a multi-atlas of healthy cases, and to determine the most optimal approach to restore normal calvarial shape. During surgery, multiple technologies are available to ensure accurate translation of the preoperative virtual plan into the operating room. Patient-specific cutting guides and templates can be designed and manufactured to assist during osteotomy and remodeling. Then, intraoperative navigation and augmented reality visualization can provide real-time guidance during the placement and fixation of the remodeled bone. Finally, 3D photography enables intraoperative surgical outcome evaluation and postoperative patient follow-up. This chapter summarizes recent literature on all these technologies, showing how their integration into the surgical workflow could increase reproducibility and reduce inter-surgeon variability in open cranial vault remodeling procedures

    Real-time tool detection for workflow identification in open cranial vault remodeling

    Get PDF
    Deep learning is a recent technology that has shown excellent capabilities for recognition and identification tasks. This study applies these techniques in open cranial vault remodeling surgeries performed to correct craniosynostosis. The objective was to automatically recognize surgical tools in real-time and estimate the surgical phase based on those predictions. For this purpose, we implemented, trained, and tested three algorithms based on previously proposed Convolutional Neural Network architectures (VGG16, MobileNetV2, and InceptionV3) and one new architecture with fewer parameters (CranioNet). A novel 3D Slicer module was specifically developed to implement these networks and recognize surgical tools in real time via video streaming. The training and test data were acquired during a surgical simulation using a 3D printed patientbased realistic phantom of an infant’s head. The results showed that CranioNet presents the lowest accuracy for tool recognition (93.4%), while the highest accuracy is achieved by the MobileNetV2 model (99.6%), followed by VGG16 and InceptionV3 (98.8% and 97.2%, respectively). Regarding phase detection, InceptionV3 and VGG16 obtained the best results (94.5% and 94.4%), whereas MobileNetV2 and CranioNet presented worse values (91.1% and 89.8%). Our results prove the feasibility of applying deep learning architectures for real-time tool detection and phase estimation in craniosynostosis surgeries.This work was supported by projects PI18/01625 (Ministerio de Ciencia, Innovación y Universidades, Instituto de Salud Carlos III and European Regional Development Fund “Una manera de hacer Europa”). Luis Hernández Álvarez was supported by CSIC Project 202050E304 (CASDiM)

    Effectiveness of Automatic Planning of Fronto-orbital Advancement for the Surgical Correction of Metopic Craniosynostosis

    Get PDF
    The surgical correction of metopic craniosynostosis usually relies on the subjective judgment of surgeons to determine the configuration of the cranial bone fragments and the degree of overcorrection. This study evaluates the effectiveness of a new approach for automatic planning of fronto-orbital advancement based on statistical shape models and including overcorrection.The authors have no financial interest in relation to the content of this article. This work was supported by grants R42 HD081712 (Eunice Kennedy Shriver National Institute of Child Health and Human Development), K99DE027993 (National Institute of Dental and Craniofacial Research), and PI18/01625 (Ministerio de Ciencia e Innovación, Instituto de Salud Carlos III and European Regional Development Fund “Una manera de hacer Europa”)

    Combining Surgical Navigation and 3D Printing for Less Invasive Pelvic Tumor Resections

    Get PDF
    Surgical interventions for musculoskeletal tumor resection are particularly challenging in the pelvic region due to their anatomical complexity and proximity to vital structures. Several techniques, such as surgical navigation or patient-specific instruments (PSIs), have been introduced to ensure accurate resection margins. However, their inclusion usually modifies the surgical approach making it more invasive. In this study, we propose to combine both techniques to reduce this invasiveness while improving the precision of the intervention. PSIs are used for image-to-patient registration and the installation of the navigation’s reference frame. We tested and validated the proposed setup in a realistic surgical scenario with six cadavers (12 hemipelvis). The data collected during the experiment allowed us to study different resection scenarios, identifying the patient-specific instrument configurations that optimize navigation accuracy. The mean values obtained for maximum osteotomy deviation or MOD (maximum distance between the planned and actual osteotomy for each simulated scenario) were as follows: for ilium resections, 5.9 mm in the iliac crest and 1.65 mm in the supra-acetabular region, and for acetabulum resections, 3.44 mm, 1.88 mm, and 1.97 mm in the supra-acetabular, ischial and pubic regions, respectively. Additionally, those cases with image-to-patient registration error below 2 mm ensured MODs of 2 mm or lower. Our results show how combining several PSIs leads to low navigation errors and high precision while providing a less invasive surgical approach.This work was supported by the Ministerio de Ciencia e Innovación, Instituto de Salud Carlos III, and European Regional Development Fund ‘‘Una manera de hacer Europa,’’ under Project PI18/01625.Publicad

    Augmented reality as a tool to guide psi placement in pelvic tumor resections

    Get PDF
    Patient-specific instruments (PSIs) have become a valuable tool for osteotomy guidance in complex surgical scenarios such as pelvic tumor resection. They provide similar accuracy to surgical navigation systems but are generally more convenient and faster. However, their correct placement can become challenging in some anatomical regions, and it cannot be verified objectively during the intervention. Incorrect installations can result in high deviations from the planned osteotomy, increasing the risk of positive resection margins. In this work, we propose to use augmented reality (AR) to guide and verify PSIs placement. We designed an experiment to assess the accuracy provided by the system using a smartphone and the HoloLens 2 and compared the results with the conventional freehand method. The results showed significant differences, where AR guidance prevented high osteotomy deviations, reducing maximal deviation of 54.03 mm for freehand placements to less than 5 mm with AR guidance. The experiment was performed in two versions of a plastic threedimensional (3D) printed phantom, one including a silicone layer to simulate tissue, providing more realism. We also studied how differences in shape and location of PSIs affect their accuracy, concluding that those with smaller sizes and a homogeneous target surface are more prone to errors. Our study presents promising results that prove AR’s potential to overcome the present limitations of PSIs conveniently and effectively.This research was funded by project PI18/01625 (Ministerio de Ciencia e Innovación, Instituto de Salud Carlos III and European Regional Development Fund “Una manera de hacer Europa”)

    Surgical navigation, augmented reality, and 3D printing for hard palate adenoid cystic carcinoma en-bloc resection: case report and literature review

    Get PDF
    Adenoid Cystic Carcinoma is a rare and aggressive tumor representing less than 1% of head and neck cancers. This malignancy often arises from the minor salivary glands, being the palate its most common location. Surgical en-bloc resection with clear margins is the primary treatment. However, this location presents a limited line of sight and a high risk of injuries, making the surgical procedure challenging. In this context, technologies such as intraoperative navigation can become an effective tool, reducing morbidity and improving the safety and accuracy of the procedure. Although their use is extended in fields such as neurosurgery, their application in maxillofacial surgery has not been widely evidenced. One reason is the need to rigidly fixate a navigation reference to the patient, which often entails an invasive setup. In this work, we studied three alternative and less invasive setups using optical tracking, 3D printing and augmented reality. We evaluated their precision in a patient-specific phantom, obtaining errors below 1 mm. The optimum setup was finally applied in a clinical case, where the navigation software was used to guide the tumor resection. Points were collected along the surgical margins after resection and compared with the real ones identified in the postoperative CT. Distances of less than 2 mm were obtained in 90% of the samples. Moreover, the navigation provided confidence to the surgeons, who could then undertake a less invasive and more conservative approach. The postoperative CT scans showed adequate resection margins and confirmed that the patient is free of disease after two years of follow-up.This work has been supported by projects PI18/01625 (Ministerio de Ciencia, Innovación y Universidades, Instituto de Salud Carlos III and European Regional Development Fund “Una manera de hacer Europa”) and IND2018/TIC-9753 (Comunidad de Madrid)

    Craniosynostosis surgery: workflow based on virtual surgical planning, intraoperative navigation and 3D printed patient-specific guides and templates

    Get PDF
    Craniosynostosis must often be corrected using surgery, by which the affected bone tissue is remodeled. Nowadays, surgical reconstruction relies mostly on the subjective judgement of the surgeon to best restore normal skull shape, since remodeled bone is manually placed and fixed. Slight variations can compromise the cosmetic outcome. The objective of this study was to describe and evaluate a novel workflow for patient-specific correction of craniosynostosis based on intraoperative navigation and 3D printing. The workflow was followed in five patients with craniosynostosis. Virtual surgical planning was performed, and patient-specific cutting guides and templates were designed and manufactured. These guides and templates were used to control osteotomies and bone remodeling. An intraoperative navigation system based on optical tracking made it possible to follow preoperative virtual planning in the operating room through real-time positioning and 3D visualization. Navigation accuracy was estimated using intraoperative surface scanning as the gold-standard. An average error of 0.62 mm and 0.64 mm was obtained in the remodeled frontal region and supraorbital bar, respectively. Intraoperative navigation is an accurate and reproducible technique for correction of craniosynostosis that enables optimal translation of the preoperative plan to the operating room. © 2019, The Author(s).This work has been supported by Ministerio de Ciencia, Innovación y Universidades, Instituto de Salud Carlos III, project “PI18/01625”, co-funded by European Regional Development Fund (ERDF), “A way of making Europe”

    Multicamera Optical Tracker Assessment for Computer Aided Surgery Applications

    Get PDF
    Image-guided interventions enable the surgeon to display the position of instruments and devices with respect to the patient's imaging studies during surgery by means of a tracker device. Optical trackers are commonly chosen for many surgical applications when high accuracy and robustness are required. OptiTrack is a multicamera optical tracker whose number of sensors and their spatial configuration can be adapted to the application requirements, making it suitable for surgical settings. Nonetheless, no extensive studies of its accuracy are available. The purpose of this paper was to evaluate an eight-camera optical tracker in terms of accuracy, miscalibration sensitivity, camera occlusions, and tool detection in a feasible clinical setup. We studied the tracking accuracy of the system using a robotic arm (~μm precision) as the gold standard, a single reflective marker, and various tracked objects while the system was installed in an operating room. Miscalibration sensitivity was 0.16°. Mean target error was 0.24 mm for a single marker, decreasing to 0.05 mm for tracked tools. Single-marker error increased up to 1.65 mm when five cameras where occluded although 75% of the working volume showed an error lower than 0.23 mm. The accuracy was sufficient for navigating the collimator in intraoperative electron radiation therapy, improving redundancy and allowing large-working volumes. The tracker assessment we present and the validated miscalibration protocol are important contributions to image-guided surgery, where the choice of the tracker is critical and the knowledge of the accuracy in situations of camera occlusion is mandatory during surgical navigation
    corecore